- Home
- Thermostats
- 01231.1-00 ETF012 Enclosure Humidity & Temp Control w/ External Sensor (1-meter cable) 0 to 60°C 50 to 90% RH 24-48Vdc
01231.1-00 ETF012 Enclosure Humidity & Temp Control w/ External Sensor (1-meter cable) 0 to 60°C 50 to 90% RH 24-48Vdc
$158.00
Product Description
ETF_012 Electronic Hygrotherm with External Sensor (1-meter cable)
* Efficient temperature & humidity control
* Operating temperature down to -40°F/°C
* High switching capacity
* Optical LED in each adjustment knob when operating
* 35mm DIN Rail Mount
Switch difference (temperature) | 3.6°F (2K) ± 1K tolerance at 77°F (25°C) & 50% RH |
Switch difference (humidity) | 4% RH ± 1% tolerance at 77°F (25°C) & 50% RH |
Reaction time (humidity) | approx. 5 sec. |
Contact type | SPDT / change-over contact (relay) |
Service life | UL: NO/NC > 30,000 cycles |
VDE: NO/NC > 15,000 cycles | |
Max. Switching capacity (Relay output) | 10A resistive / 1.6A inductive @ 240Vac |
0.6A @ 60Vdc | |
Max. Inrush current | 30A VAC for 10 seconds |
Connection | 5-pole terminal, clamping torque 0.5Nm max., solid wire & stranded wire (w/ wire end ferrule) 14 awg max. (2.5mm²) |
Housing | plastic according to UL94 V-0, light grey |
Mounting | molded clip for 35mm DIN rail, EN60715 |
Mounting position | vertical |
Operating/Storage temperature | -40 to +140°F (-40 to +60°C) |
Operating / Storage humidity | max. 95 % RH (non-condensing) |
Dimensions | 3.0x2.4x1.7" (77x60x43mm) |
Weight | approx. 10.5 oz (300g) |
Protection type | IP20 |
Approvals | cUL (UL File No. E164102), VDE |
Cable 1-meter | Operating voltage | Setting range temperature | Setting range humidity |
01231.0-00 | 100-240VAC, 50/60Hz | 0 to +60°C | 50 to 90% RH |
01231.9-00 | 100-240VAC, 50/60Hz | +32 to +140°F | 50 to 90% RH |
01231.1-00 | 24-48Vdc | 0 to +60°C | 50 to 90% RH |
Cable 2-meter | Operating voltage | Setting range temperature | Setting range humidity |
01231.0-01 | 100-240VAC, 50/60Hz | 0 to +60°C | 50 to 90% RH |
01231.9-01 | 100-240VAC, 50/60Hz | +32 to +140°F | 50 to 90% RH |
01231.1-01 | 24-48Vdc | 0 to +60°C | 50 to 90% RH |